Login New User
Register here

HomeAbout UsProductsQualityContact Us






 
HVAC R Chemicals

We offer chemicals for HVAC and HVAC/R systems. We offer inhibited glycol which prevents metal corrosion. Mono Ethylene Glycol uninhibited would form glycolic acid which would react with iron to form reddish color. This can be prevented using our corrosion inhibitors or buying inhibited Glycol. We also offer Propylene glycol which used for chilling system. Propylene Glycol coolant is used in chillers. Our formulated coolants are best for cooling and chilling system and work in all kinds of cooling water

Contact Now:
Prime Laboratories
No. 504, Meridian
Apartments, Basheerbagh
Hyderabad - 500 063
Andhra Pradesh, India
Phone: +91 40 2322 5550 Fax: +91 40 2322 3177
Email: info@primelabs.in
Antiscalants for chilling system
Biocides for chilling system
Corrossion Inhibtors for coolents
Descalant for chilling system
Coolants
Calcium Chloride Fused
.................................................................................................................................................................................................................
Antiscalants for chilling system

We offer SCALEGARD range of Antiscalant to be used in closed loop cooling circuit.

 

PRODUCT CODE

KEY CHARACTERISTICS

APPLICATION

SCALEGARD 360

Liquid scale preventive , controls hardness and inhibits scale formation

Water based system with Sodium Chloride and Calcium chloride

SCALEGARD 361

Liquid scale preventive , controls hardness and inhibits scale formation

Glycol based chilling system

SCALEGARD 362

Liquid scale preventive , controls hardness and inhibits scale formation

Water based chilling system



[ Download Brochure ]
...............................................................................................................................................................................................................
Biocides for chilling system

We offer BIOGARD range of biocides for used in cooling systems.

 

PRODUCT NAME

KEY CHARACTERISTICS

APPLICATIONS

BIOGARD 503

Powerful microbiocide in liquid form

Controls bacterial and algal growth in the system

BIOGARD 504

Broad spectrum microbiocide in powder form

Provide superior biocidal effectiveness

BIOGARD 550

A blend of penetrants & surfactants

Keep cooling water system clean to maximize efficiency and polymeric dispersant



[ Download Brochure ]
...............................................................................................................................................................................................................
Corrossion Inhibtors for coolents

We offer ROTODINE range of Corrosion Inhibitors to be used in closed loop cooling circuit.

 

PRODUCT CODE

KEY CHARACTERISTICS

APPLICATION

ROTODINE  300

Corrosion preventive liquid

Water based chilling system using Sodium Chloride or Calcium Chloride

ROTODINE 301

Glycol based chilling system

Liquid scale preventive , controls hardness and inhibits scale formation

ROTODINE 302

Water based chilling system

Liquid scale preventive , controls hardness and inhibits scale formation



[ Download Brochure ]
...............................................................................................................................................................................................................
Descalant for chilling system

We offer ROTO KLEEN range of cleaners / descalant for heat exchangers systems to increase heat transfer.

PRODUCT CODE

KEY CHARACTERISTICS

APPLICATION

ROTOKLEEN 700

Descaling chemical liquid

To remove hard water born scales from internal surfaces of heat exchangers and boilers

ROTOKLEEN 701

Descaling chemical powder

To remove hard water born scales from internal surfaces of heat exchangers and boilers



[ Download Brochure ]
...............................................................................................................................................................................................................
Coolants

We offer ROTOCOOL range of high performance coolants cleaners / descalant for heat exchangers systems to increase heat transfer.

PRODUCT CODE

KEY CHARACTERISTICS

APPLICATION

ROTOCOOL 100

Inhibited Glycol , gives extra cooling and scale free system

General cooling systems

ROTOCOOL 101

Inhibited Glycol , gives extra cooling and scale free system

Low sub zero cooling systems



[ Download Brochure ]
...............................................................................................................................................................................................................
Calcium Chloride Fused

PARAMETERS

SPECIFICATION

UNITS

Appearance

White

 

Calcium Chloride as CaCl2.2H2O

70%

 

Magnesium (as MgCl2)

0.7%

max.

Sulphate (SO4)

0.05%

max.

Iron

20 ppm

max.

Heavy Metal (Pb)

10ppm

max.

pH (10% solution) :

6.5-8.5

 

Alkalinity [as Ca(OH)2 ]

: 0.10%

max.



[ Download Brochure ]
...............................................................................................................................................................................................................
[ Top ]