Acid Corrosion Inhibitor

We offer a wide range of Acid Corrosion Inhibitors, which caters to the demands of various industries for pre-commissioning and post operative descaling (chemical cleaning) of boilers, pipelines, evaporators, heat exchangers and cooling towers. These are competent to lessen direct corrosion damage to boilers, cooling tower pipelines, heat exchangers and power plants during various processes such as oil field acidisation, scale removing, metal cleaning for galvanizing, pickling, tinning and electroplating. Our range works efficiently at ambient temperature as well as at elevated and higher temperature range, while offering efficient corrosion inhibition. These acid inhibitors have excellent wetting property, which facilitates acid penetration. This assists in removing different types of scales without difficulty. With the help of our range, pitting embrittlement is avoided and on the whole metal loss is negligible.

We offer complete range of acid inhibitors. We also offer specialized high performance acid inhibitor depending on client requirements. These corrosion inhibitor can be used for different kinds of acids. We also specialized range of pickling inhibitors for hydrochloric / sulphuric acid pickling.


Features:

         Pleasant odor

         Stable in pickling solution

         Minimal edge corrosion

         Offers high degree of restraining action against HCl attack on steel base

         Inhibition value rises from 92% with rise in concentration level raised

         Provides uniformly pickled metal surfaces with shiny surfaces

         Wetting properties for uniformly pickled surface free from smut or ingrained scale

         We also supply acid inhibitors for hydrochloric, sulphuric, sulfamic and nitric acids

 

 

Contact Now:
Prime Laboratories
No. 504, Meridian
Apartments, Basheerbagh
Hyderabad - 500 063
Andhra Pradesh, India
Phone: +91 40 2322 5550 Fax: +91 40 2322 3177
Email: info@primelabs.in
Acid Corrosion - Inhibitor
.................................................................................................................................................................................................................
Acid Corrosion - Inhibitor

PRODUCT

TYPE OF ACID

CONCENTRATION USE

TEMPERATURE

ROTODINE 213

SPECIAL

Hydrochloric Acid

1% to 2% by Volume of Concentration Acid

Room Temperature to 90C

ROTODINE 213

Hydrochloric Acid

1% to 2.5% by Volume of Concentration Acid

Room Temperature to 80C

ROTODINE 210

Hydrofluoric Acid

0.1% to 0.5% of Dilute Acid Solution

Room Temperature to 75C

ROTODINE 119

Sulphuric Acid, Phosphoric Acid

1% to 2% by Volume of Concentration Acid

Room Temperature to 100C

ROTODINE 92

Citric Acid

0.2% to 2.5% by Weight of Concentrated Acid

Room Temperature to 70C

ROTODINE 130

Sulfamic Acid

0.2% to 2.5% by Weight of Concentrated Acid

Room Temperature to 80C



[ Download Brochure ]
...............................................................................................................................................................................................................